Hunan Zhongliankang Medical Technology Co.,Ltd.

CARE FOR YOU, MAKE WITH LOVE IN CHINA

Manufacturer from China
Active Member
5 Years
Home / Products / Finger Pulse Oximeter /

250 Bpm Blood Oxygen Heart Rate Finger Monitor With Wrist Cord

Contact Now
Hunan Zhongliankang Medical Technology Co.,Ltd.
City:xiangtan
Province/State:hunan
Country/Region:china
Contact Person:MrsCathy Zhou
Contact Now

250 Bpm Blood Oxygen Heart Rate Finger Monitor With Wrist Cord

Ask Latest Price
Video Channel
Model Number :ZLK-PO1
Place of Origin :China
MOQ :100PCs
Price :USD 3-4/Pcs
Payment Terms :L/C, D/A, T/T,
Delivery Time :5-8 work days
Packaging Details :100PCs/Carton Carton Weight:5.5KG Carton Size:54*41*29CM
Color :customized
Certificate :ISO13485
Power :2 *AAA 1.5V batteries
Display :OLED display screen
Power Consumption :Smaller than 30mA
SpO2 Measuring Range :0%- 100%
Pulse Rate Measuring Range :30 bpm - 250 bpm
Material :ABS plastic
Accuracy :±2bpm or±2% select larger
Automatic turn off :5 seconds
Net weight :53g
Gross weight :86g
Size :85*66*40mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Function Specification

Display Information Display Mode
The Pulse Oxygen Saturation(SpO2) LED
Pulse Rate(PR) LED
Pulse Intensity (bar -graph) LED
Pulse wave LED
SpO2 Parameter Specification
Measuring range 0%~-100%, (the resolution is 1%).
Accuracy 70%~100%±2%, Below 70% unspecified.
Optical Sensor

Red light (wavelength is 660nm)

Infrared (wavelength is 880nm)

Pulse Parameter Specification
Measuring range 30bpm~250bpm (the resolution is 1 bpm)
Accuracy ±2bpm or±2% select larger
Pulse Intensity
Range Continuous bar-graph display, the higher display indicate the strong pulse
Battery Requirement
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery
Battery Useful Life
Two batteries can work continally for 20 hours
Dimensions and Weight
Dimensions 57(L) x 31(W) x 32(H) mm .
Weight About 50g (with the batteries)

250 Bpm Blood Oxygen Heart Rate Finger Monitor With Wrist Cord

250 Bpm Blood Oxygen Heart Rate Finger Monitor With Wrist Cord

Environment Requirements

Storage Environment

a) Temperature :-40℃~+60℃

b) Relative humidity :<95%

c) Atmospheric pressure :500hPa~1060hPa

Operating Environment

a) Temperature :10℃~40℃

b) Relative Humidity :s75%

c) Atmospheric pressure :700hPa~1060hPa

1) Display Format: OLED Display;

SpO2 Measuring Range: 0%- 100%;

Pulse Rate Measuring Range: 30 bpm - 250 bpm;

Pulse Wave Display: columniation display and the waveform display.

2) Power Requirements: 2 x1.5V AAA alkaline battery(or using the rechargeable

battery instead), adaptable range: 2.6V~3.6V.

3) Power Consumption: Smaller than 30mA.

4) Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.

5) Measurement Accuracy: ±2% in stage of 70%-100% SpO2 , and meaningless

when stage being smaller than 70%.±2 bpm or±2% (select larger) for Pulse Rate.

6) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate

can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse

rate error is +2 bpm or±2% (select larger).

7) Resistance to surrounding light: The deviation between the value measured

in the condition of man-made light or indoor natural light and that of darkroom is

less than ±1%.

8) It is equipped with a function switch. The Oximeter can be powered off in case no

finger is the Oximeter within 5 seconds.

9) Optical Sensor

Red light (wavelength is 660nm, 6.65mW)

Infrared (wavelength is 880nm, 6.75mW)

Troubleshooting

Trouble Possible Reason Solution

The SpO2 and Pulse Rate can not be displayed normally

1. The finger is not properly positioned.

2. The patient's SpO2 is too low to be detected.

1. Place the finger properly and try again.

2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right.

The SpO2 and Pulse

Rate are not

displayed stably

1. The finger is not placed inside deep enough.

2. The finger is shaking or the patient is moving.

1. Place the finger properly and try again.

2. Let the patient keep calm

The device can not

be turned on

1. The batteries are drained or almost drained.

2. The batteries are not inserted properly.

3. The malfunction of the device.

1. Change batteries.

2. Reinstall batteries.

3. Please contact the local service center.

The display is off

suddenly

1. The device will power off

automatically when it gets no signal within 5 seconds.

2. The batteries are almost drained.

1. Normal.

2. Change batteries.

Inquiry Cart 0