Product Name:
Athlet Home Use Medical Wholesale Blood Oxygen Saturation Monitor Fingertip Pulse Oximeter
Function Specification
Display Information | Display Mode |
The Pulse Oxygen Saturation(SpO2) | LED |
Pulse Rate(PR) | LED |
Pulse Intensity (bar -graph) | LED |
Pulse wave | LED |
SpO2 Parameter Specification | |
Measuring range | 0%~-100%, (the resolution is 1%). |
Accuracy | 70%~100%±2%, Below 70% unspecified. |
Optical Sensor | Red light (wavelength is 660nm) Infrared (wavelength is 880nm) |
Pulse Parameter Specification | |
Measuring range | 30bpm~250bpm (the resolution is 1 bpm) |
Accuracy | ±2bpm or±2% select larger |
Pulse Intensity | |
Range | Continuous bar-graph display, the higher display indicate the strong pulse |
Battery Requirement | |
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery | |
Battery Useful Life | |
Two batteries can work continally for 20 hours | |
Dimensions and Weight | |
Dimensions | 57(L) x 31(W) x 32(H) mm . |
Weight | About 50g (without the batteries) |
Features
CCURATE AND RELIABLE - Accurately determine your SpO2 (blood oxygen saturation
levels), pulse rate and pulse strength in 10 seconds and display it conveniently on a large
digital LED display.
SPORT/HEALTH ENTHUSIASTS - For sports enthusiasts like mountain climbers,
skiers, bikers or anyone interested in measuring their SpO2 and pulse rate. SpO2 and
Pulse Rate now faces instead of away from the user for easy read.
EASY TO USE - Taking a reading is easy, just clip it on to your finger and turn it on at
the press of a button.
ACCOMODATES WIDE RANGE OF FINGER SIZES - Finger chamber with SMART
Spring System. Works for ages 12 and above.
Troubleshooting
Trouble | Possible Reason | Solution |
The SpO2 and Pulse Rate can not be displayed normally
| 1. The finger is not properly positioned. 2. The patient's SpO2 is too low to be detected.
| 1. Place the finger properly and try again. 2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right. |
The SpO2 and Pulse Rate are not displayed stably
| 1. The finger is not placed inside deep enough. 2. The finger is shaking or the patient is moving. | 1. Place the finger properly and try again. 2. Let the patient keep calm
|
The device can not be turned on
| 1. The batteries are drained or almost drained. 2. The batteries are not inserted properly. 3. The malfunction of the device. | 1. Change batteries. 2. Reinstall batteries. 3. Please contact the local service center.
|
The display is off suddenly
| 1. The device will power off automatically when it gets no signal within 5 seconds. 2. The batteries are almost drained. | 1. Normal. 2. Change batteries.
|